Fire Protection Systems
October 02, 2024 | BCSP Staff GuideFire Protection Systems
Make sure your building has what it needs
Fires in the workplace can develop from a variety of sources. Equipment related to cooking, heating, or electrical systems can spark them. Unplanned chemical reactions and performing hot work can be a culprit. Poor housekeeping, smoking in the workplace, and even arson also account for a significant portion of fires.
The Hub Guide to Fire Prevention in the Workplace offers tips for keeping fires from ever beginning. But, in the event one does strike, how do you put it out? And how do you protect the people who may be within the building?
It starts with having the proper systems in place. The International Building Code (IBC) and U.S. National Fire Protection Association (NFPA) thoroughly outline wide-ranging codes and standards. This guide will offer general information related to fire alarms, suppression systems, and extinguishers.
Fire Alarms
A proper fire alarm system is crucial to protecting lives in instances of workplace fires. These systems are designed to detect fires and alert building occupants, allowing them to evacuate to safety via designated routes of egress. (These routes should be illuminated and marked with signs indicating the route of egress, and all doors serving as exits identified.)
Fire alarms typically detect the presence of fires through various smoke and/or heat detectors to which the system is connected. They can also be manually initiated by pulling the handles on alarms throughout a building. Once initiated, the system emits sounds and lights to alert occupants to the threat.
The IBC and NFPA outline the type of fire alarm systems required for different types of commercial buildings. Ensure your fire alarm system is designed by a qualified person, properly installed by qualified professionals, and then regularly tested and maintained. It is generally recommended to have fire alarms replaced every 10 years.
Smoke detectors should be placed on every floor. They should appear in all offices, hallways, storage areas, bathrooms, stairways, indoor parking areas, and anywhere else a fire could start.
Commercial fire alarm systems are typically powered by the building’s electricity, while batteries or generators may provide backup power. Make sure devices powered in any primary or secondary capacity by batteries have those batteries checked and replaced as part of routine maintenance schedules.
Fire Classes
Before diving into fire suppression systems and extinguishers, it is important to understand that fires come in five classes, depending on fuel type:
- Class A – Ordinary combustible materials (wood, cloth, paper, rubber, plastics)
- Class B – Flammable liquids, combustible liquids, petroleum greases, flammable gases, alcohols
- Class C – Electrical equipment
- Class D – Combustible metals, magnesium, titanium, lithium
- Class K – Combustible cooking media like vegetable oil, animal oils, and fats
The types of potential fires for your environment must be considered when determining what type of suppression agents to have installed.
Fire Suppression Systems
There are various types of fire suppression systems designed for various environments and various types of fires. Some utilize water, others foam, and others gases or chemical agents. All are designed to sense a fire and then spring into action to extinguish it.
Each type of fire suppression system should be designed and installed by qualified professionals and should be regularly maintained to ensure proper working order when needed.
Here is a general look at the different types of fire suppression systems:
- Sprinkler systems
These are the most common type of fire suppression system seen in commercial buildings. A piping system distributes water to sprinkler heads located throughout the building. The sprinkler heads detect heat and activate when the temperature reaches a certain point, expelling water to suppress the fire. At the same time, the sprinkler head activation triggers the building’s alarm system to alert occupants to the fire. Only sprinkler heads in the vicinity to the fire activate, to limit water damage.
- Water mist systems
These systems use pipes and nozzles to disperse fine water droplets when fire is detected by sensors. The mist cools the area and displaces oxygen to suppress the fire. By using minimal water, these efficient systems leave less water damage than traditional sprinkler systems.
- Chemical foam suppression systems
These are prevalent in environments with large amounts of flammable or combustible liquids. A chemical concentrate is mixed with water, often in a bladder tank, to produce a foam that is then distributed through pipes. It is discharged through devices such as nozzles and sprinklers, expanding to form a thick foam blanket that cools and smothers the fire. The system detects heat and activates automatically, targeting only specific areas where fire is detected.
- Foam deluge systems
These operate in a similar fashion to the chemical foam systems just described. The main difference is that, while chemical systems are target specific areas, foam deluge systems provide total coverage. All discharge devices release foam at the same time across the entire area covered by the system. They are beneficial in high-risk areas where rapid response is needed.
- Pneumatic heat detection tubes
These are compact and mobile extinguishers, useful for suppressing fires in small areas. As the name suggests, this type of system features gas-filled tubes to detect fire. When the temperature reaches a designated threshold, the tubes burst and the drop in pressure within the system triggers the release of the fire suppression agent – this could be water, foam, dry chemicals, or gases. Because it operates pneumatically, it does not require a power source.
- Pressurized gas system
These systems, also known as clean agent systems, are useful for areas with sensitive equipment such as electronics or archives because they use chemical agents, inert gases, or carbon dioxide and, as such, do not leave water damage. Sensors detect the presence of fire and release the agent through a system of pipes and nozzles. Depending on the type of suppression agent used, these systems interrupt the combustion process by absorbing heat or reducing or displacing oxygen. Note: Because these systems often displace oxygen, they are not used in areas where people are present.
Fire Extinguishers
Employers are also responsible for installing fire extinguishers and for providing periodic maintenance to ensure they are in working order. In the United States, regulations from the Occupational Safety and Health Administration (OSHA) require one extinguisher for every 3,000 square feet of a building and at least one on every floor of a multistory building. Greater regulations exist for work in and around flammable or combustible liquids or gases. Employees should know where these extinguishers are located so they can access them when needed.
There are different types of extinguishers designed to fight the different types of fires listed earlier in this guide:
- Water Extinguishers – For Class A fires
- Carbon Dioxide Extinguishers – For Class B or C fires
- Dry Chemical Extinguishers – For Class A, B, or C fires
- Dry Powder Extinguishers – For Class D fires
- Class K Extinguishers – For Class K fires (These form a foam blanket to smother the fire.)
Extinguishers also come in various sizes, typically ranging from 4 to 20 pounds, and should be selected based on the size of the space. Be sure the type of extinguisher you use is the proper one for the type of fire you are facing. The dry chemical extinguisher is the most common because of its ability to fight Class A, B, and C fires.
If you detect a fire, first sound the alarm and call the fire department. Then make sure you have a safe evacuation path that is unblocked by the fire, smoke, or heat. You should only attempt to put out the fire if it is in the incipient stage. As you fight the fire, stay six (6) to eight (8) feet from the flames and keep this clear exit path at your back.
When it comes to using the fire extinguisher, follow the PASS technique for the most effective results. OSHA outlines this technique as follows:
- P – PULL the pin. This will also break the tamper seal.
- A – AIM low, pointing the extinguisher nozzle (or its horn or hose) at the base of the fire.
- NOTE: Do not touch the plastic discharge horn on CO2 extinguishers, it gets very cold and may damage skin.
- S – SQUEEZE the handle to release the extinguishing agent.
- S – SWEEP from side to side at the base of the fire until it appears to be out. Watch the area. If the fire re-ignites, repeat steps 2-4.
Evacuate immediately if you have any doubt about your ability to fight the fire or if the extinguisher becomes empty but the fire has not yet been put out.
Review of Fire Protection
There are many factors to consider when it comes to fire protection systems.
What are the materials likely to cause fires in your environment? This will tell you what type of agent is needed to fight the fire. Are there sensitive or valuable items that need protection from water damage? This will help you determine what type of suppression system you need. And what are the specifics of your building and your operations? This will determine the type of alarm system you should have.
By taking all these factors into account and by following the guidelines outlined by organizations like the IBC, NFPA, and OSHA, companies can protect workers and their business from fires.
Tags: Fire Prevention, Fire Protection, Fire Safety, IBC, NFPA, OSHA,
Resource Reviews
Related Resources
Disclaimer
The information materials and opinions contained on this website are for general information and educational purposes only and should not be relied on or treated as a substitute for specific advice relevant to particular circumstances. BCSP makes no warranties, representations or undertakings about any of the content of this website (including, without limitation, any as to the quality, accuracy, completeness or fitness for any particular purpose of such content), or any content of any other website referred to or accessed by hyperlinks through this website. Although we strive to ensure reasonable accuracy, we make no representations, warranties, or guarantees, whether express or implied, that the content on our site is accurate, complete, or up to date. BCSP DISCLAIMS ALL RESPONSIBILITY FOR DAMAGES OF ANY NATURE RESULTING FROM THE USE OR RELIANCE OF ANY INFORMATION CONTAINED ON THIS SITE, AND ANY SUCH RELIANCE AND USE IS SOLELY AT YOUR OWN RISK. For more details, please review our Privacy Policy and Term Of Use.
Join our community of industry leaders!
Creating an account with us is simple with a whole bunch of benefits. You'll stay up to date on the latest releases of new resources, create your own collections, save resources for later, and more!
Sign up Now
Join our community of industry leaders!
Creating an account with us is simple with a whole bunch of benefits. You'll stay up to date on the latest releases of new resources, create your own collections, save resources for later, and more!
Sign up Now